Standard:IS 10810 (Part 13), IEC 60811-403, ASTM D 470, IS 3400 (Part 20): 1994, ISO 1431-1/1994 and ASTM 4575
Scope of application:for estimating the resistance of elastomeric and polymeric materials of cables to ozone attack
The working input power supply:220V+/-10%AC
Standard:GB12972
Scope of application:mainly applicable to the extrusion resistance of mining cables below UC-0.66KVT and UCP-1.14KV
Maximum measured load:200N
Scope of application:The flame tester is mainly suitable for components, parts, and assemblies of electrical and electronic products, household appliances
Standard:IEC884-1, GB2099.1, VDE, IEC335, GB4706.1, GB5169.5, UL1694.
Standard for igniting flames:flame height 12mm
Scope of application:is used to test the combustion characteristics of MT 818-2009 "Flame retardant cables for coal mines" under overload conditions
Standard:MT 386-1995
Combustor size:L1100× W900 × D525mm
Scope of application:It is suitable for mineral insulated cables with a rated voltage not exceeding 450/750V
Standard:BS6387
Test voltage:200-1000V
Scope of application:Mainly suitable for conducting torsion and winding tests on copper rods, aluminum rods, and steel wires
Standard:GB4909.4-2009 and GB4909.7-2009
Sample diameter range:copper rod φ 8mm or less, steel wire Ф Below 3mm
Scope of application:Used to test the ability of wires and cables to operate continuously under specified conditions under a certain fire source and time.
Standard:GB/T19216.11-2003/IEC60331-11:1999,GB/T19216.21-2003/IEC 60331-21:1999
Current range:0.1-3A
Scope of application:Suitable for the scratch and abrasion resistance test of 30mm~80mm plastic outer jackets of cables.
Standard:GB/T2951
Scraping stroke:>600mm
Scope of application:Mainly suitable for measuring the mechanical strength of PVC insulated cables or rubber
Standard:GB/T 5013.2-2008, GB/T 5013.8-2008, and GB/T 5023.2-2008
Power supply voltage:AC 380 V three-phase four wire
Scope of application:This machine is used to test the degree of thermal deformation of materials such as plastics and wire sheaths.
Standard:UL1581、GB2099
Temperature:Normal temperature~300 ℃
Standard:UL1581 sect 1080.1~1080.14, VW-1(V-ertical-specimen)Flame Test
Test method:Adjust the flame height, place the top of the flame under the specimen, burn for 15 seconds, extinguish for 15 seconds, repeat 5 times, and check the burning condition of the specimen.
Combustion chamber effective space:2.4m (length) * 1m (width) * 1.8m (height)
Scope of application:Suitable for conducting vertical slow flame propagation tests on a single wire, cable or optical cable under specified flame conditions, and can also verify the combustion of droplets under flame conditions
Standard:GB/T18380.11-2008、GB/T18380.12-2008、GB/T18380.13-2008、IEC60332-1-1:2004
Igniter:for automatic high-pressure ignition