Standard:GB/T 12441-2005 (Appendix C)
Application:of fire-retardant coatings applied to the surface of combustible substrate
Function:suitable for testing the fire retardant performance
Standard:UL1581.UL13.UL444.UL1655
Application:of wire and cable industry
Effective space:2.4m (length) * 1m (width) * 1 .8m (height)
Standard:ISO340:2004, GB/T3685-2009, GBT10707-2008
Application:of fabric core conveyor belts and steel wire rope core conveyor belts
Function:used to evaluate the reaction of the conveyor belt in a fire.
Standard:GB/T 8624-2012,GB/T 5464-2010,IS01182:2002
Application:for building materials
Function:suitable for the test method of judging the combustion performance of building materials
Standard:ISO 11925-2:2002, ISO 11925-2:2002
Application:for building materials
Function:for judging whether the building material has flammability
Standard:GB/T20285-2006
Function:suitable for test equipment for flue gas toxicity hazards of stable tobacco production.
Power supply voltage:AC220V±10% 50HZ current≤10A
Standard:GB/T9978.1-2008、GB/T9978.2-2008、GB/T9978.3-2008
Application:walls, beams, columns, floor, ceilings and roofs,
Function:suitable for load-bearing and non-load-bearing components
Standard:EN13823, GB/T 20284-2006
Application:of building materials or articles (excluding flooring materials and products specified in EC Decision 2000/147/EC)
Function:determine the fire reactivity of building materials or articles
Standard:ASTM C447-85, ASTM C411-82, ASTM C411-82
Application:of insulation products such as loosely filled insulation materials, felts
Function:suitable for the evaluation of the maximum use temperature
Standard:ASTM C447-85, ISO 8142 :1990, GB/T17430-2015, ASTM C411-82
Application:of thermal insulation products such as loosely filled insulation materials
Function:suitable for the evaluation of the maximum use temperature
Standard:GB/T18380.31-2008、IEC60332-3-10-2018
Application:of vertically installed bundled wires and cables or optical cables
Function:used to evaluate the ability of vertically installed bundled wires
Standard:ISO5660-1:2002, GB/T16172-2007
Application:important for predicting the fire hazard and flame retardant prevention treatment
Working environment temperature:0°C-50°C