Standard:GB/T10801.2-2002,GB/T8626-2007
Application:for fireproof building materials
Function:for judging whether building materials have flammability under specified conditions
Standard:ASTM D 3675,ASTM E 162
Application:of building surface materials (ASTM E162) and foams (ASTM D3675)
Function:uses gas-fired radiant panels to test the flammability
Standard:BS 476 Part 6 A1: 2009, GB/T 17658-1999
Application:of walls and ceilings
Function:for measuring the flame propagation characteristics of materials
Standard:GB/T2951
Application:of 30mm~80mm plastic outer jackets of cables
Function:Suitable for the scratch and abrasion resistance test
Standard:GB/T 5013.2-2008, GB/T 5013.8-2008, and GB/T 5023.2-2008
Application:of PVC insulated cables or rubber insulated
Function:suitable for measuring the mechanical strength
Standard:GB/T 5013-2006, GB12666.6 and IEC60331
Application:of mineral insulated cables and wires and cables with fire-resistant layers
Function:Suitable for testing the fire resistance characteristics
Standard:GB/T18380.11-2008, GB/T18380.12-2008, GB/T18380.13-2008
Application:on a single wire, cable or optical cable under specified flame conditions
Function:Suitable for conducting vertical slow flame propagation tests
Standard:GB/T18380.31-2008 and IEC60332-3-10-2018
Scope of application:of vertically installed bundled wires, cables, or optical cable
Function:Used to evaluate the ability of vertically installed bundled wires
Standard:GB/T17650.1-1998, GB/T17650.2-1998 and IEC60754-1:1994
Scope of application:for low and halogen-free flame retardant cables
Function:suitable for determining the total amount of halogen acid gas
Standard:GB/T5023.2-2008, IEC60227-2:2003, GB/T 5013.2-2008
Scope of application:suitable for detecting the dynamic bending test of rubber
Sample diameter:Φ6-φ32mm (standard with two sets of fixtures)
Standard:UL1581、GB2099
Scope of application:to test the degree of thermal deformation of materials
Temperature:Normal temperature~300 ℃
Door limit protection:do not close the door, even if the power-on point experiment starts, the equipment does not have any response, the software has: the safety door is not closed prompt
Voltage zeroing protection:If the power is suddenly cut off during the experiment, it will automatically return to the zero position after the next boot to ensure that the initial voltage is at the zero position
Termination voltage protection:ial voltage is at the zero position (3) Termination voltage protection: The termination voltage can be set by software to ensure that if there is an abnormal rise to the specified voltage during the step-up process, it will automatically terminate and ret