Home ProductsInsulation Testing Machine

50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength

Certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
Customer Reviews
Before I buy the machine, I see our partner use your machine, after receive it, all is good. thanks, hope make deal next time too.

—— Max Will

At the beginning I worry about if your company can delivery in time, It turns out your company is good, no delay,A pleasant collaboration.

—— Peter Huang

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Mr Hussain

Professional quotation, professional technology, so that we receive timely goods, trustworthy enterprises.Hope we can still cooperate next time!

—— Mr. Paul Garry

I'm Online Chat Now

50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength

50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength
50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength 50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength 50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength 50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength

Large Image :  50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength

Product Details:
Place of Origin: China
Brand Name: DAXIAN
Certification: CE, ISO 9001
Model Number: DX8388
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set
Price: Negotiation
Packaging Details: Plywood wooden case, seaworthy packing
Delivery Time: 15-25 days after deposit
Payment Terms: L/C,T/T,D/A
Supply Ability: Five sets per month

50kV AC DC Voltage Breakdown Tester DX8388 IEC 60243 ASTM D149 for Solid Insulation Dielectric Strength

Description
Test Voltage: AC 0-50kV / DC 0-50kV Continuously Adjustable Transformer Capacity: 10 KVA
Boosting Speed: 50, 100, 200, 500, 1000, 2000 KV/s (6 Gears) Voltage Measurement Accuracy: <= 2%
Leakage Current Selection: 1-20 MA Test Methods: AC Test, DC Test
Boosting Method: Automatic Programmable Boosting Power Supply: AC 220V 50/60Hz
Dimensions: 1400 X 1040 X 1500 Mm Weight: 200 Kg
Applicable Standards: IEC 60243-1, IEC 60243-2, ASTM D149, GB1408.1, GB1408.2
Highlight:

50kV AC DC breakdown tester

,

IEC 60243 dielectric strength tester

,

solid insulation testing machine

DX8388 50kV AC/DC Voltage Breakdown Tester for Solid Insulation Materials

The DX8388 voltage breakdown testing machine measures the dielectric breakdown strength and withstand voltage time of solid insulating materials under power frequency (48–62 Hz) or equivalent DC voltage, in air or in insulating oil medium. It is built for laboratories, material research centres and quality control departments that need repeatable dielectric strength data.

Standards Complied With

  • IEC 60243-1 / GB1408.1 – Electrical strength of solid insulating materials, power frequency tests
  • IEC 60243-2 / GB1408.2 – Corresponding DC voltage tests
  • GB/T1695-2005 – Power frequency breakdown voltage strength and withstand voltage of vulcanised rubber
  • GB/T3333, GB12656, ASTM D149

Applicable Materials

Plastic sheet and film, resin, mica, ceramics, silicone rubber, glass, insulating paint, laminates and other solid insulating materials. Both continuous uniform boosting and stepwise boosting modes are available: voltage is applied to the specimen until breakdown, the breakdown voltage is recorded and the breakdown strength is calculated. In rapid-rise mode the voltage is raised to a preset value and held, giving the withstand voltage of the specimen.

Key Features

  • AC 0–50 kV and DC 0–50 kV continuously adjustable test voltage with 10 kVA transformer capacity
  • Six programmable boosting rates: 50, 100, 200, 500, 1000 and 2000 kV/s (electrical automatic speed regulation)
  • Voltage measurement accuracy within ±2%, leakage current selectable from 1–20 mA
  • AC and DC test modes with automatic programmable boosting for unattended test sequences
  • Oil tank specimen fixture for liquid-medium tests, protecting operators during flashover

Main Technical Parameters

Test voltage AC 0–50 kV / DC 0–50 kV, continuously adjustable
Transformer capacity 10 kVA
Breakdown voltage 0–50 kV
Boosting speed 50 / 100 / 200 / 500 / 1000 / 2000 kV/s, 6 gears
Boosting regulation Electrical automatic speed regulation
Voltage measurement accuracy ≤ 2%
Leakage current selection 1–20 mA
Test methods AC test, DC test
Boosting method Automatic programmable boosting
Power supply frequency 50 Hz sine wave
Power supply AC 220 V 50/60 Hz
Dimensions 1400 × 1040 × 1500 mm
Weight 200 kg

Service

Factory calibration report, English operation manual, one-year warranty and remote technical support are provided with every unit. Custom test voltage levels and specimen fixtures can be engineered on request.

Contact Details
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Person: Sophia Su

Tel: +86-13266221899

Send your inquiry directly to us (0 / 3000)