Product Details:
|
| Standards: | GB/T 11785-2005, ISO 9239-1 | Heat Flux Meter Range: | 0-15 KW/m2 |
|---|---|---|---|
| Heat Flux Accuracy: | +/-0.2 KW/m2 | Radiant Panel Size: | 300 X 450 Mm, Approx. 900 C Service |
| Panel Inclination: | 30 Degrees, Adjustable | Flux Distribution: | 200 Mm: 9.1+/-0.4 KW/m2; 400 Mm: 5.0+/-0.4 KW/m2; 600 Mm: 2.4+/-0.2 KW/m2 |
| Exhaust Velocity: | 2.5+/-0.2 M/s | Exhaust Capacity: | 39-85 M3/min, Stepless Adjustable |
| Flame Height: | 60-120 Mm Adjustable | Pilot Burner: | OD 10 Mm, ID 6 Mm, 35 Holes Of 0.7 Mm |
| Thermocouple: | K Type, 3.2 Mm Stainless Steel Sheathed | Fuel Gas: | Propane, 0.026+/-0.002 L/s (user Supplied) |
| Power Supply: | AC 220V +/-10%, 50 Hz, Max. 5 KW | Burn Chamber Size: | L1420 X W1200 X H2300 Mm |
| Control Cabinet Size: | 2.2 X 1.2 X 2.4 M | Net Weight: | Approx. 350 Kg |
| Control: | Computer Control, Auto Timing, Data Printout | ||
| Highlight: | Radiant Heat Flux Test Apparatus,Flooring Materials Fire Tester,GB/T 11785-2005 ISO 9239-1 Tester |
||
The DX8401 is a dedicated laboratory instrument for evaluating the reaction-to-fire performance of horizontal flooring materials that are ignited by a small flame and exposed to an inclined radiant heat field. It is used by flooring manufacturers, testing laboratories and third-party certification bodies to measure flame spread and heat response of complete flooring assemblies under controlled laboratory conditions.
Every critical parameter, from radiant flux distribution at nine points of the panel to duct velocity, is verified against the tolerances defined in these standards, so test reports can be submitted to customers and regulators with confidence.
The apparatus is suitable for testing virtually all horizontal flooring materials, including:
Because the complete flooring assembly is tested, any change of backing material, underlay or substrate is reflected in the result. This helps manufacturers compare formulations, validate incoming materials and support declaration of performance documentation.
| Parameter | Specification |
|---|---|
| Heat flux meter range | 0 – 15 kW/m² |
| Heat flux meter accuracy | ±0.2 kW/m² |
| Heat flux meter precision | < ±3% |
| Thermal radiation pyrometer | 400 – 600 °C, accuracy ±0.5 °C |
| Black body temperature error | ±5 °C |
| Radiant panel | Porous refractory, 300 mm × 450 mm, approx. 900 °C service |
| Panel inclination | 30°, adjustable |
| Flux distribution | 200 mm: 9.1 ± 0.4 kW/m²; 400 mm: 5.0 ± 0.4 kW/m²; 600 mm: 2.4 ± 0.2 kW/m² |
| Exhaust velocity | (2.5 ± 0.2) m/s |
| Exhaust capacity | 39 – 85 m³/min, steplessly adjustable |
| Thermocouples | K type, 3.2 mm stainless steel sheathed |
| Pilot burner | Outer ø10 mm, inner ø6 mm, 35 holes of ø0.7 mm |
| Flame height | 60 – 120 mm, adjustable |
| Ignition | High voltage electronic ignition |
| Fuel gas | Propane, (0.026 ± 0.002) L/s, supplied by user |
| Cooling water | 15 °C – 25 °C |
| Burn chamber size | L1420 × W1200 × H2300 mm |
| Control cabinet size | L × W × H: 2.2 × 1.2 × 2.4 m |
| Power supply | AC 220 V ±10%, 50 Hz; max. 5 kW |
| Net weight | Approx. 350 kg |
The system consists of two main sections — the burn chamber and the control cabinet — delivered ready for installation, commissioning and operator training. Our engineering team provides calibration guidance and technical support so your laboratory can start testing shortly after delivery.
Our team brings extensive experience in manufacturing reaction-to-fire and materials testing instrumentation in accordance with EN, ISO and ASTM standards. Equipment is supported by an after-sales team providing spare parts, calibration guidance and technical service.
Contact Person: Sophia Su
Tel: +86-13266221899