Home ProductsFire Testing Equipment

GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks

Certification
china DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
china DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
Customer Reviews
Before I buy the machine, I see our partner use your machine, after receive it, all is good. thanks, hope make deal next time too.

—— Max Will

At the beginning I worry about if your company can delivery in time, It turns out your company is good, no delay,A pleasant collaboration.

—— Peter Huang

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Mr Hussain

Professional quotation, professional technology, so that we receive timely goods, trustworthy enterprises.Hope we can still cooperate next time!

—— Mr. Paul Garry

I'm Online Chat Now

GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks

GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks
GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks

Large Image :  GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks

Product Details:
Place of Origin: China
Brand Name: DAXIAN
Certification: ISO9001
Model Number: DX8220
Payment & Shipping Terms:
Minimum Order Quantity: One set
Price: US$2000-$30000
Packaging Details: Wooden case
Delivery Time: 15 work days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability: 1 sets per month

GB/T16556 Mask Flame Retardancy Test Device, Used For Testing The Flame Retardant Performance Of Masks

Description
Ambient Temperature: -5℃ To 30℃ Relative Humidity: ≤85%
Power Supply Voltage And Power: 220V±10%,50HZ,100W Burner Flame: The Temperature At 250mm Reaches 950℃±50℃
Flame Application Time: Infinitely Adjustable Gas Source: Propane
Test Sample: Mask
Highlight:

GB/T16556 mask flame retardancy tester

,

mask flame retardant test device

,

fire testing equipment for masks

Features: Automatic timing, digital display
1. Compliant with standards: It is strictly developed in accordance with the main technical parameters of the national standard GB/T16556.


2. Scope of application: This instrument is suitable for testing the flame retardant performance of face masks. It has six burners to apply flames to the test samples, and the test time is digitally displayed.

 

2. Test Procedure:
1. Connect the power supply and gas source of the instrument, and check whether the "Pressure Adjustment", "Flow Adjustment", and "perpetual light Adjustment" on the instrument panel are in the off position.
2. Open the door of the test chamber, move the head mold to install the test sample on it, adjust the distance between each burner and the test sample to 250mm according to the national standard, and then manually move the sample away from the burner.
3. Turn on the power switch and the main valve of the gas source on the instrument, adjust the "perpetual light adjustment" knob on the panel, and light the perpetual light with an open flame. The flame length should be about 20mm. Press the "? "button on the display on the instrument panel Press the "▲" key after pressing the key, and the display will show "1005".
Adjust the "pressure Regulation" on the instrument to make the pressure gauge reading around 0.12Mpa.
4. Press the "Run" key to adjust the "Flow Regulation". At this time, the burner will ignite. Adjust the air feed nut at the lower end of the burner. The temperature at 250mm of the flame is measured to be (950±50) ℃ with a thermometer. Press the "Reset" key and the burner flame will go out.
5. Then adjust the display on the panel and press "?" After pressing the key, press the "▲" key to display "0005". Manually move the test sample to the test position and press the "Run" key. The burner will ignite and the display will start timing. After 5 seconds of flame application, the burner will automatically go out and the continuation time will start timing. Pay attention to observe whether the sample continues to ignite after flame application. If the continuation stops, press the "Timing" key on the instrument and the display will stop timing.
6. Record the afterburning time and the observed phenomena.
7. Replace the new sample and repeat operations 3.2 to 3.6. After the test is completed, turn off the power supply and gas source, and clean and maintain the combustion chamber and other components.

Contact Details
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Person: Miss. Sophia Su

Tel: +86-13266221899

Send your inquiry directly to us (0 / 3000)