Building Component Fire Resistance Horizontal Furnace EN1363-1 Standard

Lab Testing Machine
October 23, 2025
Category Connection: Lab Testing Machine
Brief: Discover the Building Component Fire Resistance Horizontal Furnace EN1363-1 Standard, designed for testing fire resistance of reinforced concrete walls, steel structures, and more. This furnace meets ISO834-1 standards and offers high efficiency for large-scale fireproof partitions and components.
Related Product Features:
  • Tests reinforced concrete and steel structure load-bearing walls with a fire area of 4200×4800mm.
  • Supports fire resistance tests for non-load-bearing wall components like fireproof doors and windows.
  • Features a furnace net size of 4200×4800×1500mm for large-scale testing.
  • Conforms to ISO834-1:1999 standards for fire resistance testing.
  • Includes thermocouples and pressure sensors for accurate temperature and pressure measurements.
  • Uses propane or liquefied gas with a flow range of 0-100L/min for combustion.
  • Equipped with a mechanical loading device for homogeneous or eccentric loading simulations.
  • Computer-controlled system for real-time data display and storage.
Faqs:
  • What types of building components can be tested with this furnace?
    The furnace can test reinforced concrete walls, steel structure walls, fireproof doors, windows, glass, and large fireproof partitions.
  • What standards does this furnace comply with?
    It complies with ISO834-1:1999 standards for fire resistance testing of building components.
  • What is the maximum loading capacity of the furnace?
    The total axial load capacity is 15000kN, with upper and lower eccentric loads of 1000kN each.