Product Details:
|
| Temperature Range: | -40C To +85C | Temperature Fluctuation: | <= +/-1C |
|---|---|---|---|
| Temperature Uniformity: | <= +/-2C | Humidity Range: | 30-98% RH |
| Humidity Deviation: | +/-3% FS | Test Capacity: | 12 PV Modules |
| Inner Chamber Size: | 1.5 X 2.5 X 1.5 M | Outer Chamber Size: | 2.5 X 3.0 X 2.5 M |
| Inner Material: | SUS#304 Stainless Steel Mirror Plate | Control System: | Programmable Touch Screen Controller |
| Communication: | RS-485 With PC Software | Power Supply: | 380V 60Hz |
| Highlight: | PV module humidity freeze test chamber,IEC 61215 thermal cycling chamber,85C 98RH environmental test chamber |
||
The DX9183 is a large-capacity walk-in environmental chamber designed for IEC 61215 thermal cycling (TC200) and humidity-freeze (HF10) testing of photovoltaic modules. It reproduces the severe temperature and humidity profiles that modules face in the field, so manufacturers can verify power degradation, insulation integrity and long-term reliability before certification.
| Item | Specification |
|---|---|
| Model | DX9183 |
| Temperature range | -40°C to +85°C |
| Temperature fluctuation | ≤ ±1°C |
| Temperature deviation | ≤ ±1°C |
| Temperature uniformity | ≤ ±2°C |
| Heating / cooling rate | Meets IEC 61215 requirements |
| Humidity range | 30-98% RH |
| Relative humidity deviation | ±3% FS; 85°C ±2% RH; 90°C ±2% RH |
| Humidity fluctuation | ±2% RH |
| Humidity uniformity | ≤ 2% RH |
| Test capacity | 12 test modules (customisable) |
| Inner chamber size | Approx. 1.5 × 2.5 × 1.5 m (L × W × H) |
| Outer chamber size | Approx. 2.5 × 3.0 × 2.5 m (L × W × H) |
| Inner material | SUS#304 stainless steel mirror plate |
| Outer material | Anti-rust steel plate with baked paint finish |
| Insulation | High-density rigid PU foam and glass insulation wool |
| Control system | Programmable controller with automatic calculation, touch screen, Chinese / English interface |
| Communication | RS-485 with PC software for data storage, printing and download |
| Refrigerant | New HFC environmentally friendly refrigerant with automatic switching valve |
| Power supply | 380 V 60 Hz |
PV module manufacturers, third-party testing laboratories, research institutes and quality inspection centres use the DX9183 for IEC 61215 design qualification, batch sampling and failure analysis of crystalline silicon and thin-film modules.
Factory acceptance testing before shipment, on-site installation and commissioning, operator training, and a 12-month warranty with lifetime technical support. Chamber dimensions can be engineered to your module size and throughput.
Contact Person: Sophia Su
Tel: +86-13266221899