|
Product Details:
|
| Model: | DX8315A | Application: | UV Aging Testing Of Laminated Glass |
|---|---|---|---|
| Standard: | EN ISO 12543-4:2011 | Equipment Size: | 1700 X 1500 X 1900 Mm |
| Inside Dimensions: | 1390 X 1390 X 1100 Mm | Light Source: | OSRAM Ultra-Vitalux 300W Imported Lamp, 1000h Lifespan |
| Number Of UV Lamps: | 16 Pcs | Power: | 6.5 KW |
| Current: | 30 A | Power Supply: | 220 V |
| Test Quantity: | 9 Pcs | Temperature Control Range: | 45°C ± 5°C On Sample Surface |
| Radiation Intensity: | 900 W/m2 ± 100 W/m2 | Lamp To Sample Distance: | Greater Than 500 Mm |
| Testing Time: | 2000 H | Interference Sound: | ≤ 75 DB |
| Fan Power: | ≤ 25 W X 4 | Compressor Power: | 2.5 HP |
| Warranty: | 12 Months | ||
| Highlight: | Laminated Glass UV Aging Test Chamber,16 OSRAM UV Lamps Test Chamber,EN ISO 12543-4 Aging Chamber |
||
The DX8315A Laminated Glass Durability Test Chamber is built for UV aging testing of laminated glass. It reproduces long-term sunlight exposure in a controlled chamber so that blistering, delamination, yellowing and haze development can be evaluated before the glass reaches the facade.
Testing apparatus for EN ISO 12543-4:2011.
| Model | DX8315A |
|---|---|
| Application | UV aging testing of laminated glass |
| Standard | EN ISO 12543-4:2011 |
| Equipment Size | 1700 mm × 1500 mm × 1900 mm |
| Inside Dimensions | 1390 mm × 1390 mm × 1100 mm |
| Light Source | OSRAM Ultra-Vitalux 300W original imported lamp, 1000 hour lifespan |
| Number of UV Lamps | 16 pcs |
| Power / Current | 6.5 kW / 30 A |
| Power Supply | 220 V |
| Test Quantity | 9 pcs |
| Temperature Control Range | 45 °C ± 5 °C on the sample surface |
| Radiation Intensity | 900 W/m² ± 100 W/m² total radiation on specimen surface |
| Lamp to Sample Distance | Greater than 500 mm |
| Testing Time | 2000 h |
| Interference Sound | ≤ 75 dB |
| Fan Power | ≤ 25 W × 4 |
| Compressor Power | 2.5 HP |
The chamber is a complete test station rather than a bare light box: light source, irradiation metering, temperature control, recording and heat management are supplied together, so a laboratory can start EN ISO 12543-4 aging programmes without sourcing extra instrumentation. The 2000-hour design duty matches the duration required for laminated glass durability assessment, and the 2.5HP cooling system keeps lamp output and sample temperature within tolerance across the full run.
Tell us your specimen size, target standard and voltage requirement, and our engineers will confirm the configuration before shipment.
![]()
Contact Person: Sophia Su
Tel: +86-13266221899