Product Details:
|
| Test Station: | 1 Station | Sample Size: | L400*W200 |
|---|---|---|---|
| Air Source: | LPG Or Natural Gas | Gas Pressure: | 3.92KPa Adjustable |
| Flame Time: | 0~99 S/min Can Be Set Freely. | Combustion Angle: | 0 ~ 45 ° Adjustable |
| Highlight: | PLC control fire testing equipment,single station carpet fire tester,carpet resistance fire testing equipment |
||
PLC Control Single Station Carpet Flame Resistance Testing Equipment
Scope of application:
Suitable for carpet flame retardancy, to detect the flame retardant carpet and heat shrinkage.
Comply with the standards:
Meet the requirements of ISO6925, BS6307, BS4790, GB/T 14768 related standards.
The surrounding and bottom of the test chamber are made of thermal insulation materials such as insulating tiles and steel structures. A mirror with an angle of 45° is installed at the top to observe the test conditions.
The equipment includes the following parts: M16 (hexagonal) nut, weight 30+3/-2g, A2 steel, total 5 steel rings, square metal plate, light grid, configuration potholder: one, dual timing configuration : One
No sealed crucible (heating oven) and drying oven (required)
Main parameters:
Test station: 1 station.
Sample size: L400*W200.
Air source: LPG or natural gas; test gas must be used for arbitration tests. (prepared by customer)
Gas pressure: 3.92KPa adjustable.
Flame time: 0~99s/min can be set freely.
Combustion angle: 0 ~ 45 ° adjustable.
Burner: brass, made by our company.
Flame height: 24mm adjustable.
Ignition system: high voltage electronic ignition.
Power Requirements: AC220(±10%)V/50HZ
Components, materials:
Appearance size of the instrument: 353mm × 260mm × 920mm
The size of the box is: 380×380×380mm
The chassis material is made of 304 stainless steel. The CNC machine tool is formed by bending and arcing, which makes it more clean and beautiful.
Control system: The control box adopts the relay control system. All electronic originals adopt the well-known domestic brands and can better ensure the working performance and detection accuracy of the machine.
Environmental conditions of use:
There is no strong electromagnetic radiation source nearby.
There is a proper maintenance space around the equipment.
Temperature: 10 to 30°C.
AC220V/50HZ.
Voltage allowable fluctuation range: 220V±10%.
Allowable frequency fluctuation range: 50Hz±1%.
When the equipment is not working, the temperature of the environment should be kept within +0-45°C.
Contact Person: Sophia Su
Tel: +86-13266221899