Product Details:
|
Product Name: | Particle Filtration Efficiency Tester(PFE) | Power Source: | AC220V 50Hz |
---|---|---|---|
External Dimensions: | 1650mm* 870mm*1860mm | Warranty: | 12 Months |
Test Area: | 100cm² | Weight: | 150kg |
Highlight: | Particle Filtration Efficiency Test Mask Tester,ENI822 Particle Filtration Efficiency Test,ENI822 Mask Tester |
ENI822-3:2009 Laboratory Automated EN 143 Particle filtration efficiency tester (PFE)
Scope of application:
PFE tester is used to detect the filtration efficiency of particulate matter such as daily masks and filters. Factory direct sales, mask inhalation and exhalation filter or filtration efficiency tester automated filter tester.
Standards:
EN 149
BS EN143:2000
YY/T 2626-2019 respiratory protection products
ENI822-3:2009
NIOSH 42 CFR 84
Instrument structure:
Including spray pump, electrostatic neutralizer, cylinder, flowmeter, PLC industrial control system, fan, exhaust gas filter, flow transmitter, differential pressure sensor, touch screen computer, oil mist aerosol generator, salt spray aerosol generator, etc.
Technical Parameters:
Flow range |
(20 ~ 100) L / min, accuracy 2% |
Filtration efficiency |
(0.001 ~ 99.999)% |
Resistance |
0 ~ 2000Pa, accuracy 2% |
Test area |
100cm² |
Aerosol concentration |
(12 ~ 20) mg / m³ (salinity), (50 ~ 200) mg / m³ (oily) |
Test temperature | (25 ± 5) ℃ |
Relative humidity | (30 ± 10)% |
Gas source | flow 198L / min (0.6Mpa) at 550kPa |
Oil mist method:
The dry oil-free compressed air enters the aerosol generator at a certain flow rate to produce the aerosol with a certain particle distribution. After screening by the cascade impactor, the particles with the particle distribution meeting the standard requirements are discharged from the aerosol outlet and enter the test pipeline.
During the test, the number of particles in the upstream and downstream of the filter material is monitored, and the whole test process is conducted with a certain flow rate or air volume.
Salt spray method:
The dry oil-free compressed air enters the aerosol generator at a certain flow rate to produce the aerosol with a certain particle distribution. After screening by the cascade impactor, the particles with the particle distribution meeting the standard requirements are discharged from the aerosol outlet and enter the test pipeline.
Because the salt aerosol has static electricity, it is necessary to neutralize the salt aerosol. And for the salt aerosol, it needs to be heated to produce salt particles. The method is as follows: mixing the aerosol with heating gas, and then evaporating the water in the aerosol to produce salt particles;
Contact Person: Sophia Su
Tel: +86-13266221899