Brief: Follow along for a hands-on demonstration that highlights performance points of the DX8810A Steel Structure Fireproof Coating Test Furnace. This video showcases the furnace's compliance with ISO834-1 standards, its advanced temperature and pressure measurement systems, and its intelligent operation interface for accurate fire resistance testing.
Related Product Features:
Complies with ISO834-1 and EN1363-1 standards for fire resistance testing.
Features a four-layer furnace structure with high-temperature ceramic cotton for insulation.
Equipped with 2 high-pressure burners for optimal combustion control.
Includes a WINDOWS 7 operation interface with LabView software for real-time data display.
Advanced temperature measurement system with thermocouples for precise readings.
Pressure measurement and release systems ensure safe and controlled testing conditions.
Designed for samples up to 800cm in length, suitable for indoor and outdoor use.
Smoke exhaust system made of 304 stainless steel for durability and efficiency.
Faqs:
What standards does the DX8810A Fireproof Coating Test Furnace comply with?
The furnace complies with ISO834-1 and EN1363-1 standards for fire resistance testing.
What is the maximum sample length the furnace can accommodate?
The furnace is suitable for samples with a length of up to 800cm.
What type of fuel does the furnace use?
The furnace uses natural gas (calorific value 8500Kcal/Nm3) or industrial gas.
How is the furnace temperature controlled?
The furnace temperature is controlled via high-pressure burners with air-fuel proportional control, forming a closed-loop system with temperature feedback for optimal combustion.