Send Message
Home ProductsFire Testing Equipment

Fire Safety Helmet Flame Retardant Performance Tester

Certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD certification
Customer Reviews
Before I buy the machine, I see our partner use your machine, after receive it, all is good. thanks, hope make deal next time too.

—— Max Will

At the beginning I worry about if your company can delivery in time, It turns out your company is good, no delay,A pleasant collaboration.

—— Peter Huang

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Mr Hussain

Professional quotation, professional technology, so that we receive timely goods, trustworthy enterprises.Hope we can still cooperate next time!

—— Mr. Paul Garry

I'm Online Chat Now

Fire Safety Helmet Flame Retardant Performance Tester

Fire Safety Helmet Flame Retardant Performance Tester
Fire Safety Helmet Flame Retardant Performance Tester Fire Safety Helmet Flame Retardant Performance Tester Fire Safety Helmet Flame Retardant Performance Tester

Large Image :  Fire Safety Helmet Flame Retardant Performance Tester

Product Details:
Place of Origin: China
Brand Name: Daxian
Certification: GB/T 2812-2006, GB/T 2811-2007
Model Number: DX8221
Payment & Shipping Terms:
Minimum Order Quantity: one set
Price: Negotiation
Packaging Details: Wooden Case
Delivery Time: 15work days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Supply Ability: 15 sets per month

Fire Safety Helmet Flame Retardant Performance Tester

Description
Material: Stainless Steel Standards: GB/T 2812-2006, IS0 3873:1987
Igniter Timing Range: 0-999.9 Seconds Ambient Temperature: - 10 ℃ - 30 ℃
Supply Power: 220 V ± 10%, 50 / 60 Hz Power: 100W
High Light:

horizontal flammability tester

,

vertical flame test chamber

Fire Safety Helmet Flame Retardant Performance Tester​

 

Scope of application:


It is widely used in safety helmet production enterprises, major quality inspection units and construction engineering testing stations.

 

Fire Safety Helmet Flame Retardant Performance Tester 0

 

Performance characteristics:


1. Electronic ignition; automatic timing positioning of burner.
2. Ignition time: 0-999.9 seconds, arbitrary setting, afterburning time, smoldering time are automatically recorded, digital display.
3. Flame height: adjustable, with flame height ruler to measure flame height, and equipped with flame temperature measuring device.
4. The "push-pull" fixture, the "positioning wire" and the "guide rail" assist in positioning.
5. It is equipped with a highly sensitive combustible gas leakage alarm device, which will alarm and automatically cut off the gas if combustible gas is found.

 

Technical parameters:

 

Igniter timing range 0-999.9 seconds
Flame height measuring device 50mm scale
Ambient temperature - 10 ℃ - 30 ℃
Relative humidity ≤ 85%
Working power supply 220 V ± 10%, 50 / 60 Hz
Power 100W


1. Flame jet head: horizontal fuel nozzle with inner diameter of 10 mm;
2. Timer: indication error ± 1%, used to record afterburning time, - 0.01s;
3. Timer: the indication error is ± 1%. It is used to determine the time when the flame is applied to the safety helmet. It can set the burning time by itself. After the flame is applied, the Bunsen lamp can move away by itself;
4. Bracket: it can firmly clamp the helmet to ensure the stable position in the test, and can be moved to adjust the distance between the helmet and the flame jet head;
5. Fuel supply device: pressure control valve, gas volume control valve, gas storage tank device, which can ensure that the flame nozzle can stably eject 50 mm long blue flame
6. Combustion gas source: liquefied petroleum gas, purity more than 95% (provided by the user);
7. The inner diameter of Bunsen lamp is 10 mm ± 0.10 mm;

 

Test method:


1. The flame retardant performance tester of safety helmet should be tested in the fume hood;

 

2. The safety helmet after high-temperature impact test is clamped on the bracket according to the normal wearing direction, so that the side of the cap shell is aligned with the flame jet head, and the axis of the flame jet head is adjusted to pass through the axis of the cap shell and avoid the opening of air hole at the position of 50 mm ± 1 mm above the edge of the cap shell; the position of the bracket is adjusted so that the distance between the test area of the safety helmet and the end face of the flame jet head is 45 mm ± 1 mm, and then it is moved Open; open the gas volume control valve, adjust the flame length to 50 mm ± 2 mm, ensure that the flame has at least 15 mm blue flame; move the bracket to the position determined in front, the flame acts on the cap shell for 10 s, and cut off the gas source.


3. Record the afterburning time and possible penetration phenomenon, accurate to 0.1s.

 

Fire Safety Helmet Flame Retardant Performance Tester 1

 

Fire Safety Helmet Flame Retardant Performance Tester 2


 

Contact Details
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Person: Sophia Su

Tel: +86-13266221899

Send your inquiry directly to us (0 / 3000)